Interactive Buried Pipe & Surface Load Cross-Section
PPI Table 3-4 — AASHTO H20 Flexible/Unpaved
Cover Depth Sensitivity — Earth Load, Surface Live Load & Ring Deflection
Shows the classic shallow-vs-deep trade-off: surface live load decays with H² while soil prism load rises linearly.
Interactive Pipe Cross-Section Cutaway
Scaled OD, Min Wall (t), +12% ASTM Tolerance Band, Avg ID & Hoop Stress
WPR Derating & Surge Ceiling Gauge
Sustained ≤ PR · Recurring ≤ 1.5×PR · Occasional ≤ 2.0×PR
Figure 1-1 · Sudden Velocity Change (ΔV) vs. Transient Surge Pressure (Ps)
Live reproduction of PPI Ch. 6 p. 165 using Eq. 1-5 & Eq. 1-6 across all Standard Dimension Ratios (SDR 7.3–32.5).
Standard Dimension Ratio (SDR) Comparison Matrix — Pressure, Surge & Burial
Reconstructs PPI Tables 1-3 A/B (PR & max surge ΔV allowances) combined with live Section 3 burial & surface-load checks. Click any row to apply that DR.
| SDR | Min Wall t | Avg ID | Design PR | Working PR | Celerity a | Max ΔV (Rec) | Max ΔV (Occ) | Deflection | Buckling SF | Wall Stress | Status |
|---|
Live Substituted PPI Chapter 6 Equations
All active values from the current engineering state substituted directly into the handbook formulas.