PE6

PPI Chapter 6 · PE Pipe Design & Burial Visualizer

Buried Pipe vs. Surface Loads (Sec. 3) · Pipe Cutaway, Pressure Rating & Surge WPR (Sec. 1) · Ch. 3 Temp Curves

1. Ring Deflection PASS
0.59%
Limit ≤ 6.0% (DR 17)
2. Luscher Buckling PASS
SF 4.2
Pwc = 22.1 psi vs 7.4 psi
3. Wall Crushing PASS
63 psi
Allow 1,150 psi (SF 18.2)
4. Cover & Vacuum PASS
3.0 ft
Min ≥ 2.0 ft · Full Vac PASS

Interactive Buried Pipe & Surface Load Cross-Section

PPI Table 3-4 — AASHTO H20 Flexible/Unpaved

Adjust sliders or switch to Boussinesq mode to drag wheel load

Cover Depth Sensitivity — Earth Load, Surface Live Load & Ring Deflection

Shows the classic shallow-vs-deep trade-off: surface live load decays with H² while soil prism load rises linearly.

Click chart to set cover depth H
Design PR (Eq. 1-1) RATED
125.0 psi
HDS 1000 · FT 1.00 · AF 1.0
Working PR (WPR) PASS
125.0 psi
No surge derating
Wave Celerity (a) Eq. 1-5
837 fps
Ps = 11.25 psi / fps
Critical Time (T_CR) SUDDEN
3.58 s
Tc 2.0s ≤ T_CR (Full Surge)

Interactive Pipe Cross-Section Cutaway

Scaled OD, Min Wall (t), +12% ASTM Tolerance Band, Avg ID & Hoop Stress

WPR Derating & Surge Ceiling Gauge

Sustained ≤ PR · Recurring ≤ 1.5×PR · Occasional ≤ 2.0×PR

Figure 1-1 · Sudden Velocity Change (ΔV) vs. Transient Surge Pressure (Ps)

Live reproduction of PPI Ch. 6 p. 165 using Eq. 1-5 & Eq. 1-6 across all Standard Dimension Ratios (SDR 7.3–32.5).

Standard Dimension Ratio (SDR) Comparison Matrix — Pressure, Surge & Burial

Reconstructs PPI Tables 1-3 A/B (PR & max surge ΔV allowances) combined with live Section 3 burial & surface-load checks. Click any row to apply that DR.

Click any row to switch DR
SDR Min Wall t Avg ID Design PR Working PR Celerity a Max ΔV (Rec) Max ΔV (Occ) Deflection Buckling SF Wall Stress Status

Live Substituted PPI Chapter 6 Equations

All active values from the current engineering state substituted directly into the handbook formulas.